109
SCC
Edition 10-2008a
Calibration SCC
Step
Unit status
Error
Reason
40
(max. 800 s )
Filling cabinet with steam until B2 sen-
sor reaches 80°C (176°F)
• Heating:
ON
• Motor:
OFF
•
Humidity ap: Closed
11
71
No steam heating
Max time of 4x800sec excee-
ded
In case of „11“ check: Steam elements, SSR, Quenching sensor
50
(40 sek)
Stand-by in steam saturation
• Heating:
ON
•
Motor: ON (lowest speed)
•
Humidity ap: Closed
---
60
(min: 4x20 s;
max: 4x180 s)
Controlling with all 4 fan speeds:
•
Steam Heating: ON 50%
• Motor:
ON
•
Humidity ap: Closed
20
71
Value out of
allowable range;
Max time of 4x180sec excee-
ded
In case of „20“ check: In diagnostic mode: P1, B4, rpm
70
(4x 30 s )
Measuring at all 4 fan speeds:
Calibration value: Steam
•
Heating: ON 50%
• Motor:
ON
•
Humidity ap: Closed
60 Calibration value not in ex-
pected range (logic)
In case of „20“ check:
In diagnostic mode: P1, B4, rpm
Step 60 and 70 will run 1x for each rpm setting!
Содержание Combi Master
Страница 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Страница 2: ...2 Edition 10 2008a...
Страница 34: ...34 CM Edition 10 2008...
Страница 35: ...35 SCC Edition 10 2008a SCC Control panel...
Страница 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Страница 58: ...58 SCC Edition 10 2008a...
Страница 66: ...66 SCC Edition 10 2008a...
Страница 100: ...100 SCC Edition 10 2008a...
Страница 126: ...126 Gas Edition 10 2008a...
Страница 139: ...Edition 10 2008a 139 UltraVent...
Страница 153: ...153 Common Information Edition 10 2008a...
Страница 166: ...166 Trouble shooting SCC Edition 10 2008a...
Страница 177: ...177 SCC Edition 10 2008a...
Страница 195: ...195 Common Information Edition 10 2008a...