Installation and
servicing instructions
www.boilermag.com
Страница 1: ...Installation and servicing instructions www boilermag com ...
Страница 2: ...ng systems in larger premises such as industrial commercial and municipal buildings For other applications always consult the manufacturer before installing This product contains strong magnets Care and attention should be taken at all times during installation and servicing Do not place the magnetic cores on any ferrous surfaces or near ferrous objects Suitable personal protective equipment shoul...
Страница 3: ...hold a bucket during draining Venting Options The BoilermagXT unit is fitted with a manual vent however an additional Automatic Air Vent has been packaged along with unit separately The auto vent will automatically release the trapped air maintaining heating efficiency Please note If using the Automatic Air Vent operating pressure is reduced to 10 bar and maximum temperature to 110 C respectively ...
Страница 4: ...T in place then align and secure the fittings to connect the unit to the valves 6 Open the isolation valves and turn on the heating system 7 Complete the BoilermagXT warranty card and return to Spear Jackson 8 Run the heating system at normal operating temperature and check installation integrity Flange details Part No Inlet outlet A B Flange spacing C BMXT150 2 AAV 2 305 260 BMXT200 3 AAV 3 390 3...
Страница 5: ...nit Warning see below Be careful not to place the cores on or near ferrous items For 8 10 and 12 BMXT units the weight may exceed safe single person lifting limits Please check and if required do as 2 persons or alternatively as a mechanical lift Either place a bucket underneath or connect a hose to the 1 drain valve on the underside of the BoilermagXT Remove the drain plug and open the drain valv...
Страница 6: ...p of the unit to release any trapped air When the draining water runs clear turn off the inlet isolation valve and allow the remaining contents to drain Close the drain valve and replace the plug 6 5 7 Replace the magnetic core and hand tighten the black tricone to retain Re open both isolation valves www boilermag com ...
Страница 7: ...teel aerospace quality Surface finish Internal bead blast External powder coated black Sealing Viton o ring brown Options High temperature samarium cobalt magnetic material 250º C Warranty 10 years D C B A Part No Inlet Outlet Dia A Filter Dia B Flange spacing C Height D No magnetic rods Flow rate cubic metres hour Flange type BMXT150 2 AVV 2 DN50 170mm 260mm 280mm 5 20 PN16 BMXT200 3 AVV 3 DN80 2...
Страница 8: ...nnections Boilermag Domestic Filter 22mm 28mm Inhibitor Cleaner To optimise your heating system performance try our range of treatment products Testing Kits and Dosage Indicator Strips Electrolytic Scale Reducers Don t forget to register for your Boilermag 10 year warranty Visit www boilermag com T 44 0 114 225 0624 F 44 0 114 225 0610 service boilermag com ...