116
Gas
Edition 10-2008a
Gas volume to the bur
ne
r
RPM of burner blower motor
Max
Start
Min
correct CO
2
CO
2
too high
CO
2
too low
Blower RPM
m³ Air volume
kg or m³
of
Gas
CO
2
Values
CO
2
set:
- Correct gas - air mixture ratio
- Heat power corresponds with factory speci cation
CO
2
too high:
- gas - air mixture ratio too rich
- burner runs with overload
- Damage to heat exchanger, sooting possible
CO
2
too low:
- gas - air mixture ratio too lean
- burner runs with less power than speci ed
- Start up problems may appear (specially when unit is cold)
Actual CO
2
values
MUST
be determined by ue gas analysis.
Correct CO
2
values as well as a brief adjustment instruction you will nd on the table for burner
adjustment.
Содержание Combi Master
Страница 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Страница 2: ...2 Edition 10 2008a...
Страница 34: ...34 CM Edition 10 2008...
Страница 35: ...35 SCC Edition 10 2008a SCC Control panel...
Страница 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Страница 58: ...58 SCC Edition 10 2008a...
Страница 66: ...66 SCC Edition 10 2008a...
Страница 100: ...100 SCC Edition 10 2008a...
Страница 126: ...126 Gas Edition 10 2008a...
Страница 139: ...Edition 10 2008a 139 UltraVent...
Страница 153: ...153 Common Information Edition 10 2008a...
Страница 166: ...166 Trouble shooting SCC Edition 10 2008a...
Страница 177: ...177 SCC Edition 10 2008a...
Страница 195: ...195 Common Information Edition 10 2008a...