170
Trouble shooting SCC
Edition 10-2008a
Service 12 / Indication descaling
Steam generator scaled up; CDS display shows 9 red bars
Indication „Descaling of
steam generator necessary“
YES
Is additionally Service 12
shown?
CDS-Sensor does not create
pulses
Check CDS-Sensor, cable and
connector.
Touch function key:
degree of scale is shown
Only 2 to 3 red bars are
shown on ?
Repeat descaling procedure
NO
NO
Activate and run descaling pro-
gram. At the end of the program
the new lling volume is genera-
ted automatically.
Was the descaling
procedure suf cient?
(Visual check via level elec-
trode)
Unit ready for work
YES
NO
Water supply not suf cient:
- Water pressure too low
(below 50 kPa)
- Water lter soiled
- CDS Sensor soiled
- Water intake pipe of steam
generator scaled up
(Pipe must be descaled separa-
tely)
YES
NO
Содержание Combi Master
Страница 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Страница 2: ...2 Edition 10 2008a...
Страница 34: ...34 CM Edition 10 2008...
Страница 35: ...35 SCC Edition 10 2008a SCC Control panel...
Страница 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Страница 58: ...58 SCC Edition 10 2008a...
Страница 66: ...66 SCC Edition 10 2008a...
Страница 100: ...100 SCC Edition 10 2008a...
Страница 126: ...126 Gas Edition 10 2008a...
Страница 139: ...Edition 10 2008a 139 UltraVent...
Страница 153: ...153 Common Information Edition 10 2008a...
Страница 166: ...166 Trouble shooting SCC Edition 10 2008a...
Страница 177: ...177 SCC Edition 10 2008a...
Страница 195: ...195 Common Information Edition 10 2008a...