20
CM
Edition 10-2008
CM - Sequence of events
Mode: Hot Air;
Temp. range 30-300°C (86-572°F)
Function Step
Responsible sensor
1. Select Hot Air mode
Set temperature 30-300°C (86-572°F)
2. Select time or core temperature
3. Close cabinet door
Reed switch S3
4. Timer starts immediately
Logic on PCB
5. Hot Air supply unitl set temperature
Cabinet sensor B1
is
reached
6. Quenching (set to 90°C/194°F)
Quenching sensor B2
Note: Reduction of fan motor speed
In case the actual
temperature
in the range of
30-99°C
(86-210°F) is 2°C / 4°F higher than
the set temperature for longer than 2 minutes, the fan speed will be reduced automatically.
B1
B3
F4
M4
Y1
Y2
B2
M1
S2
B5
F3
S3
Содержание Combi Master