108
SCC
Edition 10-2008a
Calibration SCC
Step
Unit Status
Error
Reason
1
Basic conditions o.k?:
Continue with step 10
71 Basic conditions not met
10
Measurement:
Offset Diff. pressure sensor P1
• Heating:
OFF
• Motor:
OFF
• Humidity
ap:
Closed
13
Offset out of range
In case of error „13“ check:
P1 or 12V power supply to P1
20
(min: 4x20 s;
max: 4x180 s)
Controlling with all 4 fan speeds:
Steady signal of rpm and pressure
• Heating:
OFF
• Motor:
ON
• Humidity
ap:
Closed
20
71
Offset out of range
Max time of 4x180sec exceded
In case of error „20“ check:
In diagnostic mode: P1, B4, rpm
To start calibration:
Set DIP switch 1 to “on”, on pcb; Select: Basic Settings step 1.1; press START
Should an error code be displayed during calibration run, switch unit OFF and ON again, correct the
error reason and re-start calibration.
30
(4x 30 s)
Measuring at all 4 fan speeds:
Calibration value: cold cabinet
• Heating:
OFF
• Motor:
ON
• Humidity
ap:
Closed
50
Calibration value not in expected
range (logic)
In case of error „50“ check:
In diagnostic mode: P1, B4, rpm
Step 20 and 30 will run 1x for each rpm setting!
Содержание Combi Master
Страница 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Страница 2: ...2 Edition 10 2008a...
Страница 34: ...34 CM Edition 10 2008...
Страница 35: ...35 SCC Edition 10 2008a SCC Control panel...
Страница 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Страница 58: ...58 SCC Edition 10 2008a...
Страница 66: ...66 SCC Edition 10 2008a...
Страница 100: ...100 SCC Edition 10 2008a...
Страница 126: ...126 Gas Edition 10 2008a...
Страница 139: ...Edition 10 2008a 139 UltraVent...
Страница 153: ...153 Common Information Edition 10 2008a...
Страница 166: ...166 Trouble shooting SCC Edition 10 2008a...
Страница 177: ...177 SCC Edition 10 2008a...
Страница 195: ...195 Common Information Edition 10 2008a...