107
SCC
Edition 10-2008a
Calibration SCC
Calibration at the customers site must be done under the following conditions:
Changing of:
Pressure sensor P1,
1.
B4 humidity sensor,
2.
fan motor,
3.
pcb,
4.
external EEPROM,
5.
detaching of the fan wheel,
6.
replacing the air baf e or divider plate between the 2 fan motors of a oor model,
7.
installation of the appliance above 1000m (3000ft) above sea level or below sea level (dead
8.
sea), installing with Ultravent of venting extension or as a Combi Duo
Usage of a different standard rack
9.
Customer complaint for uneven cooking results
10.
Basic condition Temperatures:
Cabinet sensor Quench. sensor
Humidity sensor
B1 <40°C
B2 <45°C
B4 < 40°C
Basic condition Hardware:
Heating: OFF
Fan motor: OFF Humidity ap: Closed
Side panel must be tted; Unit must be clean, but may be wet
In order to achieve the best possible calibration values, insert
2 GN-container 20 or 40 mm deep with the opening facing downwards
in 61 and 62 units into rail 2 and 5
in 101 and 102 units into rail 3 and 7
in 201 and 202 units 3 GN container into rail 3, 10 and 17
Содержание Combi Master
Страница 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Страница 2: ...2 Edition 10 2008a...
Страница 34: ...34 CM Edition 10 2008...
Страница 35: ...35 SCC Edition 10 2008a SCC Control panel...
Страница 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Страница 58: ...58 SCC Edition 10 2008a...
Страница 66: ...66 SCC Edition 10 2008a...
Страница 100: ...100 SCC Edition 10 2008a...
Страница 126: ...126 Gas Edition 10 2008a...
Страница 139: ...Edition 10 2008a 139 UltraVent...
Страница 153: ...153 Common Information Edition 10 2008a...
Страница 166: ...166 Trouble shooting SCC Edition 10 2008a...
Страница 177: ...177 SCC Edition 10 2008a...
Страница 195: ...195 Common Information Edition 10 2008a...