4
Remote Management
55
Accessing R220 sensor readings and event logs
Sensor readings and event logs offer more detailed information than what is presented in the
MegaRAC GUI dashboard. Both can be accessed in the MegaRAC GUI or by issuing IPMI
commands.
Sensor readings
The BMC displays current and historical readings for R220 sensors, including:
•
CPU core temperatures
•
baseboard temperature
•
voltages
•
chassis security status
•
fan speeds
For further information about managed sensors, see the R220 tab in
ATCA Managed Sensors
spreadsheet.
MegaRAC GUI location: Server Health tab, Sensor Readings page
IPMI commands:
Get Sensor Reading
and
Get Sensor Event Status
System event log
The R220 system event log is generated by the BMC and can be displayed in the MegaRAC GUI
or by issuing IPMI commands.
MegaRAC GUI location: Server Health tab, Event Log page