Power supplies
The R220 is designed to support multiple 80 PLUS® Platinum or Gold efficiency power
supplies. Specifications based on the 800W AC power supply and 750W DC power supply are
shown in Tables
and
, respectively.
800W AC/DC power supply
•
Model R220RCPSU-AC
•
800W redundant AC power supply
•
Platinum efficiency
•
Hot-swappable
•
PMBus monitoring
•
Automatic voltage range selection for AC input. Acceptable inputs are:
•
200V to 240V AC, 50Hz; 4.79 Amps
•
100V to 127V AC, 60Hz; 9.9 Amps
WARNING!
To reduce the risk of electrical shock or energy hazards, comply with these
precautions:
•
Make sure you have an adequate number of properly grounded electrical outlets for your
system and any other peripheral devices.
•
The unit shall be installed in a restricted access area in accordance with the authority having
jurisdiction.
750W DC/DC power supply
•
Model R220RCPSU-DC
•
750W redundant DC power supply
•
Gold efficiency
•
Hot-swappable
•
PMBus monitoring
•
Automatic voltage range selection for DC input. Acceptable inputs are -38V to -75V DC;
24-12.5 Amps
Table 2. Power supply specifications
Output
Minimum load
Maximum load
Load reg
Ripple and noise
+12V
0.0A
65A
+/–5%
120mV P-P
+12V SB
0.0A
2.0A
+/–5%
120mV P-P
Table 3. Power supply specifications
Output
Minimum load
Maximum load
Load reg
Ripple and noise
+12V
0.5A
62A
+/–5%
120mV P-P
+12V SB
0.05A
2.1A
+/–5%
120mV P-P
Содержание R220
Страница 1: ...R220 NETWORK APPLIANCE July 2014 Setup Guide ...
Страница 32: ...3 Installing optional components 32 Figure 18 Installing removing the I O module ...
Страница 34: ...3 Installing optional components 34 Figure 20 Inserting the drive carrier into the drive cage ...
Страница 42: ...3 Installing optional components 42 Figure 27 Installing the rail kits into a threaded hole EIA 4 post rack ...
Страница 45: ...3 Installing optional components 45 Figure 29 Installing the rail kits into a Telecom 2 post rack ...