![Quantum Superloader 3 Скачать руководство пользователя страница 171](http://html2.mh-extra.com/html/quantum/superloader-3/superloader-3_user-manual_3481581171.webp)
Event Error Logs (SDLT 600 only)
Quantum SuperLoader 3 User’s Guide
153
Table 20 Hard Read Error/
Hard Write Error Block
Descriptor
Table 21 Hard Read /Hard
Write Error Field Descriptions
Long Word
Byte 03
Byte 02
Byte 01
Byte 00
1
Media ID
2
Physical Block Number (PBN)
3
Tape Address
4-12
13
Media Type
Tape Format
14
Tape Number
15
Retry Count
Logical Blk Num
(LBN)
16
Head Wear Hours
BRC Head Wear Hours
Field
Description
Media ID
Random number used to identify tapes
Physical Block Number
(PBN)
Physical block location where the error occurred. There is one physical block
for each read/write head on each track. For example, if there are four
separate heads and 10 tracks, there would be 40 physical blocks on a single
point of that media.
Tape Address
Location on tape in inches
Track Number
Track number where error occurred
Retry Count
Retry count used when reading