Bugcheck Error Logs (SDLT 600 only)
Quantum SuperLoader 3 User’s Guide
151
Table 18 Bugcheck Log Field
Descriptions
Field
Description
Event Number
: The Event Number is one of the common first line fields explained in the Event Types
sections. Below is a listing of the Bugchecks for each event number.
B810
Library Port Communications problems—Library or drive problem. If the problem
continues multiple times after you reset the drive, contact customer support.
E204
Unexpected Time 2 Interrupt—Drive problem. If the problem continues multiple times
after you reset the drive, contact customer support.
EE01
Spurious Non-Askable Interrupt—Drive problem. If the problem continues multiple
times after you reset the drive, contact customer support.
EE02
Spurious Time Interrupt—Drive problem. If the problem continues multiple times after
you reset the drive, contact customer support.
EE03
Spurious Level 5 Interrupt—Drive problem. If the problem continues multiple times
after you reset the drive, contact customer support.
EE04
Spurious Drive Comm Interrupt—Drive or Loader problem. If the problem continues
multiple times after you reset the drive, contact customer support.
EE06
Spurious Diagnostic Comm Interrupt—Drive problem. If the problem continues
multiple times after you reset the drive, contact customer support.
EE08
Watch Dog Timer Expired—SCSI bus, host controller, or drive problem. If the problem
continues multiple times after you reset the drive, contact customer support.
EE09
Spurious Power Fail—Power supply or power cables problem. If the problem continues
multiple times after you reset the drive, contact customer support.
EE0D
Spurious Level 6 Interrupt—Drive problem. If the problem continues multiple times
after you reset the drive, contact customer support.
F202
Loader Time-Out—Loader problem. If the problem continues multiple times after you
reset the drive, contact customer support.