FRU and Device ID Map
This system supports one FRU (Field Replaceable Unit), the FRU inventory data contains information such as the serial
number, part number, asset tag and short descriptive string for the FRU. The content of a FRU Inventory are specified in the
Platform Management FRU Information Storage Definition
. The Device list here is a logic device and is accessed by IPMI
FRU Command.
FRU Device ID
FRU HW Device
R/W
Size
Format
00
M/B
R/W
8192 Bytes
Per FRU format
Platform Event
Filters and Alerting
1. Platform Event Filter
The BMC implements selectable action on an event or LAN alerting base on event. By default, no any PEF entries or actions
exist, application need to configure it to enable. Other than analog sensors, all discrete sensors support PEF.
The number of Platform Event Filter Table is 40.
The number of Alert Policy Table and Alert Destination Table is 15.
The policy to match an event to Platform Event Filter Table entry is IPMI 1.5 standard.
The action support Alert,Power Off, Power Reset, and Power Cycle.
All Platform Event Filter Table is default disabled.
While SEL is full, PEF policy still works.
PEF Startup Delay and Last Processed Event tracking is not supported.
PEF table lookup isn’t correlated to log SEL to SEL Repository.
Serial Alerting is no support.