PEF/PET Alerting Commands
Command NetFn
CMD
O/M
Supported?
Get PEF Capabilities
S/E
10h
M
Yes
No
Arm PEF Postpone Timer
S/E
11h
M
Yes
No
Set PEF Configuration Parameters
S/E
12h
M
Yes
No
Get PEF Configuration Parameters
S/E
13h
M
Yes
No
Set Last Processed Event ID
S/E
14h
M
Yes
No
Get Last Processed Event ID
S/E
15h
M
Yes
No
Alert Immediate
S/E
16h
M
Yes
No
PET Acknowledge
S/E
17h
M
Yes
No
PEF Configuration Parameters
Parameter
#
Parameter Data (non-volatile otherwise noted)
Set In Process
0
Byte 1 – This bit
[7:2] – Reserved
[1:0] – 00b Set Complete
01b Set In Process
10b Reserved
11b Reserved
PEF Control
1
Byte 1
[7:4] Reserved
[3] Reserved
[2] Reserved
[1] 1b Enable event message for PEF actions
[0] 1b Enable PEF
PEF Action Global Control
2
Byte 1
[7:6] Reserved
[5] 1b Enable diagnostic interrupt, NMI in this platform
[4] Reserved
[3] 1b Enable Power Cycle
[2] Reserved
[1] 1b Enable Power Down
[0] 1b Enable Alert
Number of Event Filter
5
Byte 1
[7] Reserved
[6:0] 16 Event Filter Entry support in default platform
Event Filter Table
6
Byte 1 Set Selector
[7] Reserved
[6:0] Filter number 1 base
Byte 2:21 Filter Data
Chapter 4 — BMC