Remote Access Configuration
*1
: Disabled/
Enabled
*2
:
COM1
/COM2
*3
:
115200 8,n,1
/57600 8,n,1/38400 8,n,1/19200 8,n,1/09600 8,n,1
*4
:
None
/Hardware/Software
*5
: Disabled/
Enabled
*6
:
ANSI/
VT100/VT-UTF8
Limitation
:
When populate serial device, the remote access function must be disabled.
Control Group
User Access Level
Remote Access
Access Level 2
Serial port number
Access Level 2
Serial Port Mode
Access Level 2
Flow Control
Access Level 2
Redirection After BIOS POST
Access Level 2
Terminal Type
Access Level 2
View BMC System Event Log
Chapter 3 — BIOS
48
Select Remote Access
type.
←
Select
Screen
↑↓
Select
Item
-+ Change
Option
F1 General
Help
F10
Save and Exit
ESC Exit
Configure Remote Access type and parameters
----------------------------------------------------
Remote
Access
[Enabled]
*1
Serial port number
[COM1]
*2
Current SOL Baud Rate
115200 bps
Serial Port Mode
[115200 8,n,1]
*3
Flow
Control
[None]
*4
Redirection After BIOS POST
[Enabled]
*5
Terminal
Type
[ANSI]
*6
Server
BIOS Setup Utility
v02.66 © Copyright 1985-2009, American Megatrends, Inc.
Use +/- to traverse
The event log.
←
Select
Screen
↑↓
Select
Item
-+ Change
Option
F1 General
Help
F10
Save and Exit
ESC Exit
Total Number Of Entries:
84
----------------------------------------------------
SEL Entry Number
[1]
SEL Record ID:
0001
SEL Record Type
02(System Event)
Event Timestamp:
48s from SEL init
Generator
ID:
0020
Event Message Format Ver:
04 (IPMI ver 2.0)
Event Sensor Type
14 (Button)
Event Sensor Number:
D3
Event Dir Type:
6F
Event Data:
00 00 00
- Power Button pressed
- N/A
- N/A