Voltage Sensor
Sensor
Number
Normal LCT LNCT UNCT UCT
P3V3_STBY
36h
3.3V 3.072V 3.136V 3.456V 3.520V
P3V3
35h
3.3V 3.072V 3.136V 3.456V 3.520V
P5V
32h
5V 4.67V 4.76V 5.25V 5.34V
P12V 34h
12V
11.21V
11.40V
12.6V
12.78V
P1V8_AUX
33h 1.8V 1.68V 1.71V 1.89V 1.92V
P1V5_ICH
31h 1.5V 1.40V 1.43V 1.56V 1.60V
FAN Control and Monitoring
Fan Speed Monitoring
AST2050 senses all fans in threshold base through its internal or external tachometer sensor W83793G. All of sensors
support LNCT and LCT assertion and de-assertion. Thermal engineers also need to define these values. Below is the table
of fan speed thresholds.
Fan Sensor
Sensor
Number
Normal LCT LNCT UNCT UCT
System FAN 1
51h
N/A
1500
2000
N/A
N/A
System FAN 2
52h
N/A
1500
2000
N/A
N/A
PCI FAN
50h
N/A
1500
2000
N/A
N/A
Bus Error Detection
PCI Bus Error Detection
This feature will be done by BIOS. BIOS will record events in SEL.
Memory Bus Error Detection
This feature will be done by BIOS. BIOS will record events in SEL.
QPI Error Detection
This feature will be done by BIOS. BIOS will record events in SEL.
Processor Error Detection
Thermal Trip / Processsor Hot
Thermal Trip and Processor Hot can be detected by GPIO. When error is detected, the event will be added to SEL and the
supported action will be executed in PEF.