Chapter 4 — BMC
Sensor
Name
Sensor #
Entity ID
Insta
n
ce
Sensor Type
Event/Reading
Type
Event Triggers
Event Data
Sensor
Initialization
Sensor
Capabilities
IOH
Temp
46h 03h 01h Temperature
–
01h
Threshold
–
01h
Upper Critical Going High (A, S, R)
Upper Non-Critical Going High (A, S, R)
Upper Critical Going Low (D, S, R)
Upper Non-Critical Going Low (D, S, R)
Upper Critical threshold is comparison returned (D)
Upper Non-Critical threshold is comparison returned(D)
A=0280 D=3280 R=1818
Reading,
Threshold
7:0
6:Scan=1
5:Event=1
4:Thresh=1
3:Hyst=1
2:Type=1
1:Event=1
0:Scan=1
Default=7Fh
7:Ignore=0
6:Auto=1
5,4: Hyst
R&S=01
3,2:Thresh
R&S=10
1,0:Per
Thresh=00
Default=58h
PROC_HOT0
PROC_HOT1
21h
22h
03h
3-4
Temperature – 01h
Digital Discrete –
03h
1:State Asserted (A, D, R)
A=0002 D=0002 R=0002
Trigger
Offset
7:0
6:Scan=1
5:Event=1
4: 0
3:Hyst=0
2:Type=0
1:Event=1
0:Scan=1
Default=63h
7:Ignore=0
6:Auto=1
5,4: No Hyst=00
3,2:No
Thresh=00
1,0:Per
Event=00
Default=40h