Appendix I Troubleshooting
96
the transformer or track connections, at least
temporally, to allow you to use the RESET features.
27. The horn or whistle comes on when either
the horn or bell button is pressed.
System 1 is selected. Go to RESET Position #20 and
select "System 2."
28. The chuff sound is irregular or the engine
stops and RESETS automatically. The horn
or whistle sometimes blows by itself or there
is a delay in the whistle or horn shutting off
after I release the horn button.
The track and/or rollers are dirty or corroded. Clean
the track and replace rollers if necessary.
OR, the wrong transformer was selected in RESET
Position #19. Check to see if your QS-2+ is set for the
correct transformer or is set for "Auto Select". (see
Section 6, RESET Position #19).
29. The engine will RESET but will not go
when I interrupt the power. I hear the soft tick
of the relays when I interrupt the power but
the motor does not turn.
One or both Motor wires are not connected to the QSI
reverse unit or the ProtoSound bottom board. Check
the connections and re-solder if necessary.
OR, one or two brushes on your Lionel AC motor are
hung up in the brush guides and are not making
contact to the copper commutator on the armature.
Remove the top brush plate and clean the guide with
WD-40 and pipe cleaner rod or Q-Tips.
30. The engine only goes in one direction.
The engine is in Lock-out. Unlock the engine (see the
Quick Exit Guide.) If you want to disable the Lock-
out Feature, go to RESET Position #40 and choose
"Disabled."
OR, you may be in Automatic Operation. Go to
RESET Position #11 and choose the first choice,
"Normal Operation."
OR, you may be pressing the Direction Button too
quickly and not giving the QS-2+ system time to
change to the next direction.
OR, you may have a faulty direction button or your
transformer that is not completely shutting off the
track voltage during direction changes.
31. After running my engine in Automatic
Operation, and doing a RESET and
interrupting the power, my engine will not
return to automatic operation.
You need a high throttle setting to run automatic
operation, but the high throttle setting keeps your
engine from leaving RESET. Move the throttle to a
low setting before interrupting the power. Your engine
will return to the automatic operation you selected.