![QSI QS-2plus! Скачать руководство пользователя страница 90](http://html1.mh-extra.com/html/qsi/qs-2plus/qs-2plus_manual_3303981090.webp)
90
Appendix I: Troubleshooting
Appendix I has four sections:
•
Quick Exit Guide
•
Troubles with Direction States
•
Troubles with Sound
•
Troubles with Older Transformers
Quick Exit Guide
QS-2+ has four commands you can use should your engine misbehave. These
commands are called
Hard RESET
,
All Select, Engine Unlock
and
Operational
Clear.
Hard RESET (or QS-2+ Computer Restart)
If your engine is misbehaving (it doesn't take commands, or does something you
didn't expect) you should first try to RESET your QS-2+ computer.
T o D o A H a r d R E S E T
••
Turn the power off for 15 seconds or more
•
Turn the power back on
When you turn the power back on, you should hear "ding, ding," telling you the
QS-2+ computer has restarted successfully and you are now in RESET. If you do
not hear the double "ding," leave the power off for 30 seconds. If you still do not
hear a double "ding," try Engine Unlock (see next page).
All Select
If you get a double "ding" when you turn the power back on, but your engine is
silent and unresponsive, your engine may be de-selected. Use ALL SELECT to
start your engine.
T o D o A n A l l S e l e c t
••
Do a normal three second RESET
You are now in RESET Position #0.
••
Press and hold the Horn Button. You will hear a "ding." Continue to
hold the Horn Button down for at least three seconds
If your engine was dead, you will now hear the Air Compressor start up.
••
Release the Horn Button
You can now operate your engine.