4–Non-Interactive Commands
Command Summary
4-30
SN0054614-00 K
Run Adapter Diagnostics Read-write Buffer Test
The
{(-ex | exclude) <
target wwpn
>}
parameters specify a device that
will be excluded from the read/write buffer test.
The system shows the following information after a read/write buffer test
completes:
Loop ID/status
Data miscompare
Link failure
Loss of sync
Loss of signal
Invalid CRC
Table 4-11
lists the
<
param name
>
,
<
param alias
>
, and
<
param value
>
options.
Table 4-11. Diagnostics Parameters
Name
<param name>
Alias
<param alias>
Value
<param value>
Description
DataPattern
DP
Test pattern in hex format
a
Customized (00–FF)
Random pattern
CRPAT
b
CJTPAT
c
CSPAT
d
a
Valid two-character case-insensitive hexadecimal patterns.
b
Compliant random data pattern in a valid FC frame, as defined by the ANSI document
Methodologies for Jitter and
Signal Quality Specification - MJSQ Annex A - Test bit sequences.
00, 55, 5A, A5, AA, FF (see
Table 4-12
)
—
—
Loopback test only
Loopback test only
Loopback test only
DataSize
e
DS
8, 16, 32, 64, 128, 256, 512,
1024, 2048
Actual data transferred during
any given pass of the test
TestCount
f
TC
0–65535
0–10,000
Loopback test only
Read/write buffer test only
TestIncrement
g
TI
1–65535
1–10,000
Loopback test only
Read/write buffer test only
OnError
OE
0–2
0 = ignore
1 = stop
2 = loop on error
Table Notes
Содержание QLA2 Series
Страница 174: ...3 Interactive Commands Help Menu Command Line Option h 3 122 SN0054614 00 K Notes...
Страница 224: ...4 Non Interactive Commands Command Summary 4 50 SN0054614 00 K Notes...
Страница 256: ...A XML Format 1 XML Format 1 Tags for Each Option A 32 SN0054614 00 K Notes...
Страница 292: ...B XML Format 2 XML Format 2 Tags for Each Option B 36 SN0054614 00 K Notes...
Страница 322: ...D Help Commands D 10 SN0054614 00 K Notes...