4–Non-Interactive Commands
Command Summary
4-22
SN0054614-00 K
The data pattern must be in a two-character hexadecimal pattern in the range
of 00–FF. The hexadecimal letters can be uppercase or lowercase. The default
pattern is random, for example:
#
scli -kl(<
hba instance
> | <
hba wwpn
>) DP Random
To enter a customized value (in the range of 00–FF), type:
#
scli -kl
(<
hba instance
> | <
hba wwpn
>) DP <
param value>
In addition to a hex pattern, you can enter a compliant random data pattern
(CRPAT), jitter tolerance pattern (CJTPAT), or supply noise test sequence
(CSPAT) for a loopback test. For example:
#
scli -kl
(<
hba instance
> | <
hba wwpn
>) DP CJTPAT
Table 4-7
lists all valid data patterns:
Table 4-7. Data Pattern Values
Hexadecimal
Binary
00
00000000
55
01010101
5A
01011010
A5
10100101
AA
10101010
FF
11111111
Random
Customized (00–FF)
CRPAT
a
(loopback test only)
a
Compliant random data pattern in a valid FC frame, as defined by the
ANSI document
Methodologies for Jitter and Signal Quality
Specification - MJSQ Annex A - Test bit sequences.
CJTPAT
b
(loopback test only)
b
Compliant jitter tolerance pattern in an FC frame, as defined by the ASIC
document listed above.
CSPAT
c
(loopback test only)
c
Compliant supply noise test sequence in a valid FC frame, as defined by
the ASIC document listed above.
Table Notes
Содержание QLA2 Series
Страница 174: ...3 Interactive Commands Help Menu Command Line Option h 3 122 SN0054614 00 K Notes...
Страница 224: ...4 Non Interactive Commands Command Summary 4 50 SN0054614 00 K Notes...
Страница 256: ...A XML Format 1 XML Format 1 Tags for Each Option A 32 SN0054614 00 K Notes...
Страница 292: ...B XML Format 2 XML Format 2 Tags for Each Option B 36 SN0054614 00 K Notes...
Страница 322: ...D Help Commands D 10 SN0054614 00 K Notes...