6-28
ROTALIGN 01.2000
Advanced diagnosis & correction of soft foot
Example 6
Two large ROTALIGN readings on one side with opposite side near
zero cause suspicions of induced soft foot. Feeler gauge readings are
taken at foot D (with the largest ROTALIGN value). Presence of
parallel gap at foot D supports these suspicions. Presence of parallel
gap at foot C as well would prove induced soft foot.
Conclusion: relieve external forces (probably caused by horizontal
offset misalignment or by pipe strain).
Feeler gauges are used to examine the foot with the largest
ROTALIGN reading, but no gap is found.
Conclusion: "squishy foot:" do not add or remove shims, rather
eliminate the cause of the spring action. Recheck all four feet.