5-7
ROTALIGN 01.2000
Vertical machine alignment - measure
No. of mea-
surements
Screen after one
measurement
Indicates too few measure-
ments or too small an angle
CENTERED!
e) The TABLE option, described on page 4-48, can be used for
averaging multiple measurement sets.
f)
A 3D display of the two position detectors can be viewed by
selecting the XY VIEW softkey. Press the CURVE FIT softkey to
switch from the XY display to the YY display. See page 4-43 for a
complete description of the XY VIEW option.
CENTERED!
Measurements are now
sufficient for a result
Screen after five
measurements
d) Turn the shaft to each measurement position, rotating the shaft
clockwise, and press the corresponding numeric key.
Note, if rotation is restricted, measure at the points to which you
can turn, e.g. 3,4,5,6 and 7. At least three points are required for
a result. Additional measurements should be taken for greater
accuracy.
c) Ensure that the sensors are exactly at the chosen position and
press the numeric key corresponding to the position, e.g. "1":
Содержание ROTALIGN ALI 3.500