Diagnostics and Troubleshooting
(Firmware v3.00 and later)
Protocol Manual
ProSoft Technology, Inc.
Page 115 of 157
January 22, 2010
Viewing Data in Floating Point Format
Press
[F]
from the Database View menu. Use this command to display the data on
the current page in floating point format. The program assumes that the values are
aligned on even register boundaries. If floating-point values are not aligned as such,
they are not displayed properly.
Viewing Data in ASCII (Text) Format
Press
[A]
to display the data on the current page in ASCII format. This is useful for
regions of the database that contain ASCII data.
Returning to the Main Menu
Press
[M]
to return to the Main Menu.
4.1.5 IEC-870-5-104 Server Menu
Press
[I]
from the main menu to open the IEC-870-5-104 Server Menu.