2
About this product
The flow meter DulcoFlow
®
is intended for use
in measuring pulsing volume flows in the range
from 0.1 to 80 l/h. All parts coming into contact
with flow media are made from PVDF. This
ensures that aggressive media can also be
measured without problem. The device is
installed approximately 30 cm after the pump in
the metering line. Interfering influences, such
as air bubbles, are identified and forwarded to
the analysis unit as an error message. With the
delta, it can only be used with the fast metering
stroke version.
The DulcoFlow
®
flow meter can not only be
used for recording and measurement of volume
flows, but also for monitoring individual
metering strokes. In this case the pump is cali‐
brated to the lifting volume set at the pump. A
lower and upper limit can be entered, which if
exceeded or undershot, results in no feedback
to the pump. This creates an error message.
The connection to the pump takes place via the
input for the "Flow Control" dosing monitor
The device is designed for wall mounting.