Fault description
Cause
Remedy
There is air in the liquid end,
the chemical feed container
is empty.
n
Fill the metering tank.
n
Pull out the cable to the DulcoFlow
®
from
the pump.
n
Bleed the liquid end.
n
Plug the cable to the DulcoFlow
®
into the
socket on the pump.
There is gas in the dosing
head - leaks in the path
between the chemical feed
container and the Dulco‐
Flow
®
.
n
Repair the leak.
n
Pull out the cable to the DulcoFlow
®
from
the pump.
n
Bleed the liquid end.
n
Plug the cable to the DulcoFlow
®
into the
socket on the pump.
Blockage between Dulco‐
Flow
®
and metering tank
n
Clear the blockage.
n
Pull out the cable to the DulcoFlow
®
from
the pump.
n
Bleed the liquid end.
n
Plug the cable to the DulcoFlow
®
into the
socket on the pump.
The stroke adjustment dial
is mis-set
- see metering pump operating instructions
The feed chemical is too
viscous
- see metering pump operating instructions
11.3 All Other Faults
All other faults:
Inform your customer service department or
your ProMinent branch.
Troubleshooting
49