Requirements:
n
1 measuring cylinder which can be read sufficiently accurately
n
The metering pump suction line is fed, bubble-free into the measuring cylinder.
1.
Record the fluid level in the measuring cylinder.
2.
Change from the menu item
„calibration stroke feedback“
using the
[arrow keys]
to the menu
item
„calibration quantity“
and press key
[P]
.
ð
The menu item
„quantity corr. factor“
appears.
3.
Change from the menu item
„quantity corr. factor“
using the
[arrow keys]
to the menu item
„quantity meas. Value“
and press key
[P]
.
ð
The menu item
„actual volume“
appears.
4.
Start the metering pump.
Select the number of strokes so that the reading error at the measuring cylinder (half of
the smallest readable volume graduation divided by the metered total volume) is smaller
than the Dulcoflow measurement error.
5.
Stop the metering pump.
6.
Record the fluid level in the measuring cylinder and calculate the difference.
7.
Press key
[P]
.
ð
The menu item
„nominal volume“
appears.
8.
Adjust the value in the menu item
„nominal volume“
using the
[arrow keys]
based on this dif‐
ference and press the
[P]
key.
ð
The menu item
„corr. factor“
appears. It shows the calculated correction factor.
9.
Press key
[P]
, to return to the continuous display.
It is also possible to manually calculate the correction factor and enter it directly under
„entry“
-
„corr.
factor“
.
Settings
38
Содержание DulcoFlow DFMa series
Страница 7: ...Identity code 7 ...