8.4.2.1 "Display" menu
P
P
P
P
B0228
set-up
display
flow unit
mL/h
quantity unit
mL
damping flow
30.00 s
In the
„display“
menu, the units can be selected for the quantities and flow.
Moreover, the damping of the displayed flow values can be changed (not for quantities), if they
change too quickly / slowly in the display.
The greater the set integration constant in the menu item
„damping flow“
, the greater the damping of
the displayed flow values.
Non-metric units and their conversion
Unit
Meaning
Conversion
1 gal
1 US liquid gallon
= 3.785421 l
1 lb(s)
1 Pound
= 453.59237 g
8.4.2.2 "Counter output" menu
(identity code characteristic "signal output" "2")
P
P
P
P
P
P
P
P
P
P
B0235
set-up
counter output
puls/freq.
open-collector
counter output
puls/freq.
counter output
stroke feedback
open-collector
NPN
K factor
5000 1/mL
puls/freq.
signal output
K factor unit
1/mL
puls/freq.
error output
error
bubbles
In the
„counter output“
menu the counter output can be set either as a pulse/frequency output to
output the instantaneous flow, as an error signal or as a feedback message.
Settings
26