8.2 Checking adjustable varia‐
bles
Before you adjust the flow meter, you can
check the actual settings of the adjustable vari‐
ables:
Press the key
[ i ]
("i" for "Info"), if the
LCD screen is displaying a continuous
display - i.e. no display of the operating
menu.
ð
After every press on the
[ i ]
key,
you see a different continuous dis‐
play.
The number and appearance of the continuous
displays depends on the selected measured
variable and whether a setpoint has been
entered - see below.
The key [ i ] is used to change between
continuous displays.
Continuous display for the "Volume" measured
variable
Continuous display
Description
V:
243,32 mL
Q: 171,05 mL/h
Total quantity* V and
instantaneous volume
flow Q
V:
243,32 mL
N:
637
Total quantity* V and
number of strokes* N
V/H:
0,382 mL
%SH: 102,3 %
Volume per stroke V/
H and deviation from
the set point of the
lifting volume** %SH
* since the last reset
** if a
„volume (stroke)“
has been entered under
„Calibration
è
Stroke feedback
è
Set-point“
Continuous displays for the "Mass" measured
variable
(If
„mass“
was set under
„Mode
è
Measured variable“
.)
Continuous display
Description
m:
326,05 g
Q: 229,21 g/h
Total quantity* m and
instantaneous mass
flow Q
m:
326,05 g
N:
527
Total quantity* m and
number of strokes* N
m/H: 0,619 g
%SH: 97,8 %
Mass per stroke m/H
and deviation from the
set point of the stroke
mass** %SH
* since the last reset
** if a
„mass (stroke)“
has been entered under
„Calibration
è
Stroke feedback
è
Set-point“
Reset values
–
To reset the total quantity and
strokes, press both [arrow keys]
simultaneously.
–
In the main menu "Zero set", the total
quantity and the strokes can be set to
"zero" independently of each other.