Upper limit values
B0233
P
P
P
P
P
P
P
P
calibration
stroke feedback
mass (stroke)
0.347 g
stroke feedback
set-point
mass (stroke)
0.347 g
tolerance
tolerance (%)
lower limit
0.312 g
tolerance
limits
upper limit
0.416 g
Alternatively, the desired limits for the allowed range of the stroke mass can be entered under
„lower
limit“
and
„upper limit“
:
1.
Follow the menu path
„calibration
è
stroke feedback
è
set-point“
and press the key
[P]
.
ð
The menu item
„volume (stroke)“
displays the currently stored setpoint.
2.
Start the metering pump.
ð
The actual measured value is displayed.
3.
Turn the stroke length adjustment knob until the desired setpoint is displayed.
4.
Press key
[P]
.
ð
The displayed measured value is saved as a setpoint and the menu item
„tolerance
tolerances“
appears.
The setpoint is valid as 100%.
5.
Using the
[arrow keys]
change to the menu item
„limits“
and press key
[P]
.
6.
Turn the stroke length adjustment dial down until the desired lower limit is reached and press
key
[P]
.
7.
Analogously, proceed in the same way for the upper limit.
ð
The continuous display appears again.
8.
Stop the metering pump.
Settings
34