8.4.3.2.1 By corr. factor
B0244
P
P
P
calibration
quantity
corr. factor
101.23 %
quantity
corr. factor
calibration
stroke feedback
If the new correction factor is know in %, it can be entered directly here.
It is obtained by dividing a value you have measured yourself by the displayed value and multiplying
the result by 100.
1.
Follow the menu path
„calibration
è
stroke feedback“
.
2.
Using the
[arrow keys]
change to the menu item
„calibration quantity“
and press key
[P]
2x.
3.
Using the
[arrow keys]
Enter the
„corr. factor“
and press the key
[P]
.
ð
The continuous display appears again.
8.4.3.2.2 By meas. Value
CAUTION!
Danger with dangerous feed chemicals
Provided the following handling instruc‐
tions are followed, contact with the feed
chemical is possible.
–
If the feed chemical is dangerous,
take appropriate safety precautions
when carrying out the following han‐
dling instructions.
–
Observe the feed chemical safety
data sheet.
Depending on the set measured variable, a cal‐
ibration menu appears for:
n
Volume
n
Mass
Settings