10.1 Maintenance
Interval
Maintenance work
Regularly
Check whether the correct flow value is displayed.
If this is not the case, recalibrate the flow - see chapter "calibrate".
If stroke feedback is used: Adjust the stroke length with the metering pump run‐
ning and set just above the programmed upper limit - the flow identifier at the
pump should no longer flash.
Adjust the stroke length with the metering pump running and set just below the
programmed lower limit - the flow identifier at the pump should no longer flash.
If this is not the case, check for the cause and as necessary readjust the Dulco‐
Flow
®
- see
Ä
Chapter 8.4.3.1 „Calibrate "stroke feedback"“ on page 29
If stroke feedback is used: Check whether the stroke feedback LED (right-hand
side of the device) illuminates in time with the strokes.
If this is not the case, check for the cause and rectify as necessary.
Check whether feed chemical is coming out.
If necessary, carefully wipe the device with a soft cloth and soapy water.
10.2 Repairs
Only ProMinent of customer service authorised
by ProMinent may repair the DulcoFlow
®
flow
meter.
10.3 Disposal
CAUTION!
Environmental hazard due to electronic
waste
There are electronic components in the
device, which can have a toxic effect on
the environment.
–
Separate the electronic components
from the remaining parts.
–
Observe the current applicable regu‐
lations in your country.
Maintenance, repair and disposal
45