11.2 Pump error
To return the pump to operating status after one of the following errors, press the key [P] .
In the event of an error an LED lights up red and the flow identifier flashes.
Fault description
Cause
Remedy
The pump stops
during priming.
Due to air in the liquid end,
the DulcoFlow
®
has not
output an acknowledge
pulse.
During priming pull the cable to the DulcoFlow
®
out - the function "Flow" is disabled which the
cable is out.
The pump stop
during Dulco‐
Flow
®
set-up.
The DulcoFlow
®
has given
out too few sequential
acknowledge pulses.
Press key
[P]
.
The pump stops
while running.
There is air in the liquid end,
gaseous feed chemical.
n
Pull out the cable to the DulcoFlow
®
from
the pump.
n
Bleed the liquid end.
n
Plug the cable to the DulcoFlow
®
into the
socket on the pump.
n
Increase the number of acknowledge
pulses in the pump's menu.
Troubleshooting