About setpoint and tolerances
P
P
P
P
P
P
P
B0230
calibration
stroke feedback
volume (stroke)
0.347 mL
stroke feedback
set-point
volume (stroke)
0.347 mL
lower tolerance
-010.00 %
tolerance
tolerance (%)
upper tolerance
+020.00 %
Specify the allowed range for the lifting volume V/H via the setpoint of the lifting volume V/H and
tolerances in %:
1.
Follow the menu path
„calibration
è
stroke feedback
è
set-point“
and press the key
[P]
.
ð
The menu item
„volume (stroke)“
displays the currently stored setpoint.
2.
Start the metering pump.
ð
The actual measured value is displayed.
3.
Turn the stroke length adjustment knob until the desired setpoint is displayed.
4.
Press key
[P]
.
ð
The displayed measured value is saved as a setpoint and the menu item
„tolerance
tolerances“
appears.
The setpoint is valid as 100%.
5.
Stop the metering pump.
6.
Press key
[P]
.
7.
Set the
„lower tolerance“
with the
[arrow keys]
and press the
[P]
.
8.
Set the
„upper tolerance“
with the
[arrow keys]
and press the
[P]
.
ð
The continuous display appears again.
The desired setpoint can also be entered, without having to use the stroke adjustment dial or
the pump having to be running, directly under „volume (stroke)“ using the [arrow keys] .
Settings
30