![Promax OL-612 Скачать руководство пользователя страница 122](http://html1.mh-extra.com/html/promax/ol-612/ol-612_user-manual_1616414122.webp)
October 2014
Page
117
6 SPECIFICATIONS
DIGITAL STORAGE OSCILLOSCOPE
BANDWIDTH
100 MHz.
Channel
2+1 (External).
ACQUISITION
Mode
Normal, Peak detect, Averaging.
Sample rate (real time)
Dual CH
1 GS/s.
Single CH
2 GS/s.
INPUT
Input coupling
DC, AC, Ground.
Input impedance
1 M
Ω
±
2%, in parallel with 15 pF
±
5 pF.
Probe attenuation factor
1X, 10X, 100X, 1000X.
Max. input voltage
400 V (PK-PK) (DC + AC PK-PK).
Bandwidth limit
20 MHz, 100 MHz.
Channel – channel isolation
50 Hz: 100:1
10 MHz: 40:1
Time delay between channel
(typical)
150 ps.
HORIZONTAL SYSTEM
Sampling rate range
Dual CH
1 S/s
∼
1 GS/s
Single CH
1 S/s
∼
2 GS/s
Interpolation
(sin x)/x
Record length
2 M points on each channel.
Scanning speed (S/div)
2 ns/div
∼
100 s/div, step by 1
∼
2
∼
5.
Sampling rate /
relay tine accuracy
±
100 ppm.
Interval (
Δ
T) accuracy
(DC
∼
100MHz)
Single
±
(1 interval time + 100 ppm x r 0.6 ns).
Average >16
±
(1 interval time + 100 ppm x r 0.4 ns).