Operating Instructions
TM-150-D-A-XL
Operation
34 / 47
V1
GB
When engine breakdown the load/kerb stones does not fall down (check valve).
Residual vacuum lowers the operating valve unit/lifting hose unit with the sucked in load/kerb stone slowly.
Do not use the device to jerk [sic!] seized loads/kerbstones!
No work stoppage (pause) with sucked load/kerb stone, danger of the overheating of the vacuum blower!!!
Adjust engine speed in such way that a minimum vacuum of -0.4 bar is present.