13
Instructions to activate the mechanical oil pres-
sure control are mentioned on the sticker placed
on the engine.
IMPORTANT !
Even with mechanical oil pressure monitoring
the oil level must be checked every 8 – 15
operating hours
(Chapter 5.2.1.).
4.2.
Starting the engine
Do not run the engine in closed or
badly ventilated rooms – danger of
poisoning ! Before the engine is started, al-
ways make sure that nobody is in the danger
area (moving parts on engine or machinery)
and that all safety guards are in place.
Check that the starting handle is in good condi-
tion: renew tubular grip if broken, worn drive pin
etc.
Lightly grease the sliding-contact area between
the starting handle and the guide sleeve.
14
Never use any spray starting aids.
4.2.1. Preparations for starting
– If possible, disengage the engine from any
driven equipment. The auxiliary equipment
should always be placed in neutral.
15
– Set speed control lever „1“ to a position be-
tween 1/2 START and max. START, according
to requirements. Selecting a lower engine
speed will reduce smoke when starting.
– Make sure that stop lever „2“ - if fitted - is in
the operating „START“ position.
2396 / 3
2
1
START
START
STOP
STOP
050 145 00
L3 / 250
13