Operating Instructions
TM-150-D-A-XL
Safety
12 / 47
V1
GB
3.12
Checking the Safety Devices
The lifting device is equipped with
following safety devices:
●
vacuum gauge with red danger zone
●
warning device, audible (optional)
Check these devices at the beginning of each shift (when operating in shifts) or once
a week (when operating continually).
Checking the Vacuum Gauge and the
Warning Device
Warning device monitors the operating vacuum and power failure
Switch on the lifting device.
Place the lifting device on a stone slab or similar material and apply vacuum.
Caution
: Simply apply vacuum to attach the suction pads to the stone slab. Do not lift
the
stone slab
, since it may be dropped during the test!
When the vacuum has built up, lift the edge of a suction pad to create a leak.
The reading on the vacuum gauge decreases. When the vacuum drops below
red danger zone, the warning device must sound.
Checking the Vacuum Hoses and
Hose Clamps:
Check all vacuum hoses and clamps for proper mounting and tighten the clamps if
necessary.
Checking the Vacuum Reservoir
See “Testing for Leaks"“ in chapter “Maintenance“
Correct any faults before using the device. If faults occur during operation, switch
the device off and correct the faults before continuing work with the device.
3.13
Unauthorized transportations
All unauthorized transportations with the device are not allowed!
Transportation of people and animals.
Transportation of other loads and material than described in this manual.
3.14
Unauthorized alterations
All unauthorized alterations of the device and the use of any self-made additional equipment
could cause danger and are therefore forbidden!!
Pos: 5 /=== ===== ===== ===== ===== ===== === @ 0\mod8_2.doc @ 5159 @