4.2.4. Starting in cold weather
At temperatures below app. –5 °C, always turn
the engine over to ensure that it rotates freely.
– Move the speed control lever to the START
position; Fig. 15.
– Move the decompression lever to a position
not as far round as starting position „1“
(Figures 16 and 17).
– Turn the engine over with the starting handle
until it is felt to rotate more freely (10 – 20
turns of the starting handle).
– If mechanical oil pressure monitoring is
fitted, press lever „1“ or pin „1“ in for about
15 seconds (Figs. 11 and 12).
21
22
– Remove dirt from the cover of the metering
device and the surrounding area. Pull off the
cover; Figs. 21 and 22.
– Add a free-flowing lubricating oil to the
housing until the level reaches the upper rim.
Replace the cover and press it in firmly. Two
filling operations in succession are needed.
– Turn the decompression lever until
limit stop „1“ (fig. 16 and 17).
– After this, start the engine immediately.
Chap. 4.2.1. / 4.2.2. / 4.2.3.
4.2.5. Electric starter
For preparations to start, see Chapter 4.2.1.
– The decompression lever remains in pos. „0“.
Starting procedure
23
– Insert the key
to its stop
and turn it to
position I
.
– Battery charge telltale „2“ and oil pressure
warning „3“ must light up.
1
2
3
4
5
2392 / 9
2283 / 8
16