Operating Instructions
TM-150-D-A-XL
Safety
11 / 47
V1
GB
3.8.1
Inspecting the vacuum hoses and hose clamps
●
Check that all vacuum hoses and hose clamps are securely seated. Tighten any loose connections.
3.8.2
Testing the vacuum reservoir
●
See the sub-section "Leak test" in the section ”Maintenance”
●
Rectify any detected faults before using the lifting device. If a fault becomes apparent during,
switch off the lifting device and rectify the fault.
3.9
Damages of suction plate
Avoidance of damages:
To avoid damages of the rubber seal on the suction plate (chinks, abrasion) take notice, that:
during the operation (lifting, transporting and lowering) with the device, the suction plate does not brush or pump
against other products or materials.
Otherwise the rubber seal on the suction plate could be damaged (danger of pressure loss).
Product could fall down.
Danger of accidents!
3.10
Protective equipment
The protective equipment must consist, according to the safety regulations of
the following parts:
●
Protective clothing
●
Safety gloves
●
Safety shoes
●
Hearing protector
3.11
Behaviour in Emergencies
An emergency situation exists when
●
power suddenly fails (device switches off),
●
the vacuum pressure drops below -0.42 bar to the red section on the scale of the vacuum gauge.
Lower the load immediately if possible. If this is not possible, immediately leave the dangerous area near the
load, since it will be dropped from the device.