Installation & Operation Manual TCC70XS
Page 114
4.3.21
“Serial” Serial Interfaces for Remote Control
Depending on configuration the TCC70XS is equipped with a serial interface (in
–
and output
pins at the SERIAL connector). The electrical format could be selected according to RS232 or
RS422 or RS485 standard.
Please refer to the document “RUB +TCC70XS Application: Serial Remote Control“ for details.
You will find this document at the included CD. Alternatively, you can download it from:
Serial
via Browser
Serial
via USB
Interface
Select the electrical interface
Off
Interface switched off
RS232
Interface according to RS232 standard
RS422
Interface according to RS422 standard
RS485
Interface according to RS485 standard
Protocol
Select a data protocol from the drop
–
down list
Baud Rate
Choose the baud rate:
2400
/
4800
/
9600
/
19 200
/
38 400
/
57 600
/
115 200
Data Bits
7
or
8
data bits
Parity
Select the parity mode
None
Without parity
Even
Even parity bit
Odd
Odd parity bit
Stop Bits
1
or
2
stop bits
Use Timeout
A timeout may be used for synchronization.
Timeout [ms]
Choose a timer value for the timeout counter. Please choose a value suitable to
the selected baud rate.
Termination
If RS422 has been selected, the transmitter and the receiver can get a
termination. If RS485 has been selected, the transmitter can get a termination.