Installation & Operation Manual TCC70XS
Page 73
4.2.2
Status “Time and Date“
Time & Date
external reference:
Status information about the selected real
–
time reference.
last used source
Identifies the source which has last set the internal real
–
time clock:
none
internal real
–
time clock has not set so far
external pps + serial
real
–
time reference at REF/GPI connector
ntp client
NTP client
rtc
buffered clock of the Ethernet module
manual
manual setting
current source
Identifies the current used source of real
–
time reference:
off
no source selected
external pps + serial
real
–
time reference at REF/GPI connector
ntp client
NTP client
format
Identifies the selected serial protocol, valid if
current source
shows
“external pps
+ serial
”.
time
Time currently received from the real
–
time reference.
date
Date currently received from the real
–
time reference.
last lock at
T
he moment when at last the “locked” status has bee
n received.