Step 4:
Configuration page
Insert
(3G
–
Video module):
Insert real
–
time:
Choose a window and click
Visible
.
Source =
Read
Format =
Time, HH:MM:SS
or
Time, HH:MM:SS:FF
Any other parameter can be selected freely.
Insert date:
Choose a window and click
Visible
.
Source =
Read
Format =
Date, DD MM YYYY
or
Date, DD MM YY
or any
other “
Date
“ Format.
Any other parameter can be selected freely.
5.4 Insert MTD Timer or MTD Date
Time code generators of type RUB GT or RUB GL are able to transmit MTD data in the user
data of the time code. MTD data can include stop timers, various time zones, and a date.
TCC70XS can read and decode these data. Normally MTD data will be transmitted in an LTC
format of time code. This feature is independent from the method of operating of the time
code generator.
Step 1:
Choose time code reader and configuration pages (3G
–
Video module):
At configuration page
Functions
click
Use
at
Read
,
at
Video
,
at
Insert
,
and at
LTC Read
(or at the reader of that time
code format which transports the MTD data).