Installation & Operation Manual TCC70XS
Page 79
4.3.3
“Profile”: Store and Load Setups
This module has a flash memory to store different setups. A complete set
–
up stored to the
module is ca
lled a “profile”. You can identify different profiles by a number or a name. You
can assign the “Load Profile” function to a function key or GPI
O, this enables to change the
current set
–
up during normal operation and without using a computer.
Profile
via Browser
Profile
via USB
Name
Optionally, you can enter a name to identify the profile.
Store Profile
Store
Click this button to open the “Store Profile“ window. Select a number or a
name from the “Profile“ drop–
down list, if you want you can add more
information at “Operator”, “Date”, and “Comment”. Click “ok“ to store the
complete set
–
up to internal memory of the module.
Load Profile
Load
Click this button to open the “Load Profile“ window. Select a number or a
name from the “Profile“ drop–
down
list. Click “ok“ to load the profile, this
will replace the current set
–
up. This process will interrupt the operating
mode of the module.
“Factory Settings
“ will load the default values.
Save To File
This button enables to store the current set
–
up in a file on your computer.
Load From File
This button (respectively via USB: Select “
Load Profiles...
“ from ”File”
menu)
enables to load a set
–
up from a file.