PSEN op2H-SL Series
Operating Manual PSEN op2H-SL Series
1004304-EN-01
45
Technical details Order no. 631103-631105
General
631103
631104
631105
Approvals
CE, TÜV, cULus Listed CE, TÜV, cULus Listed CE, TÜV, cULus Listed
ESPE type
2
2
2
Sensor's mode of opera-
tion
Optical
Optical
Optical
Height of protected field
600 mm
750 mm
900 mm
Resolution
Protection type
Hand
Hand
Hand
Operating range
0,2 - 6 m
0,2 - 6 m
0,2 - 6 m
Detection capability
24 mm
24 mm
24 mm
Electrical data
631103
631104
631105
Supply voltage
Voltage
24 V
24 V
24 V
Kind
DC
DC
DC
Voltage tolerance
-20 %/+20 %
-20 %/+20 %
-20 %/+20 %
Max. power consumption
receiver
4,2 W
4,2 W
4,2 W
Max. power consumption
transmitter
1,6 W
1,6 W
1,6 W
Protection class
3
3
3
Optical data
631103
631104
631105
Opening angle
-5 - 5 deg
-5 - 5 deg
-5 - 5 deg
Used wavelength range
850 nm
850 nm
850 nm
Semiconductor outputs 631103
631104
631105
OSSD safety outputs
2
2
2
Switching current per out-
put
300 mA
300 mA
300 mA
Times
631103
631104
631105
Supply interruption before
de-energisation
0 ms
0 ms
0 ms
Response time t1
9 ms
10 ms
11 ms
Max. response time with
cascading
20 ms
20 ms
20 ms
Environmental data
631103
631104
631105
Ambient temperature
Temperature range
0 - 55 °C
0 - 55 °C
0 - 55 °C
Storage temperature
Temperature range
-25 - 70 °C
-25 - 70 °C
-25 - 70 °C
Climatic suitability
Humidity
15 ... 95 %
15 ... 95 %
15 ... 95 %
Condensation during op-
eration
Not permitted
Not permitted
Not permitted