PSEN op2H-SL Series
Operating Manual PSEN op2H-SL Series
1004304-EN-01
39
Status information
Legend
LED on
LED flashes
LED off
Display has no significance
Receiver
1
2
EDM/3
RES
OSSD
PWR
Meaning
green green
Ready for operation
red
green
Protected field is interrupted.
yel-
low
red
green
Protected field is interrupted.
EDM is activated.
yel-
low
red
green
Internal error.
Switch the safety light grid off and then on
again.
If the error persists, please contact Pilz.
yel-
low
red
green
Error in the synchronisation of the light
beams.
Check the ambient conditions and the wir-
ing.
Switch the safety light grid off and then on
again.
yel-
low
red
green
EDM error.
Check the wiring of the connected relay.
Switch the safety light grid off and then on
again.
yel-
low
yel-
low
red
green
Error in cascading.
Check the cascading and the wiring for the
cascading.
yel-
low
yel-
low
red
green
Error in restart function.
Check the ambient conditions and the wiring
for the start button.
Switch the safety light grid off and then on
again.