PSEN op2H-SL Series
Operating Manual PSEN op2H-SL Series
1004304-EN-01
36
}
PNOZmulti for safety light grid monitoring
Configure the safety light grid in the PNOZmulti Configurator with switch type 3.
}
Automation system PSS 4000 for monitoring safety light grids with the FS_LightCurtain
function block
The correct connection to the respective evaluation device is described in the operating
manual for the evaluation device. Connect the evaluation device according to the specifica-
tions in the selected evaluation device’s operating manual.
5
3
1
2
4
5
3
1
0 V
24 V
24 V
0 V
EDM
OSSD 1
OSSD 2
24 V
Restart
0 V
24 V
0 V
Restart Selection 2
4
n.c.
Receiver
Transmitter
Evaluation device
Input circuit
External supply voltage
Fig.: Dual-channel connection of the safety light grid on the input circuit of an evaluation device –
EDM deactivated, automatic restart
Checking the safety light grid
Once the safety light grid has been installed and aligned, final inspections must be carried
out before it can be put into service.
INFORMATION
This inspection may only be carried out by qualified personnel.