PSEN op2H-SL Series
Operating Manual PSEN op2H-SL Series
1004304-EN-01
29
[1]
[2]
[3]
[4]
[5]
[6]
[7]
Legend
[1] Distance from the non-connection end of the safety light grid to the position of the
C-bracket at the non-connection end = ¼ of the protected field height
[2] 2 M4 screws to attach the L-bracket
[3] M4 screw to attach the C-bracket
[4] Position the safety light grid in the C-bracket at a slight angle
[5] Push the safety light grid in the L-bracket as far as it will go
[6] M3 screw to position the clamping jaw of the C-bracket
[7] Attach the horizontal section of the L-bracket to the vertical section using M3
screws
Cascaded safety light grid
Transmitters and receivers on cascaded safety light grids are correctly aligned in exactly
the same way as a single safety light grid is aligned.
Start the alignment with the master unit and then continue with the slave unit (when there
are two slave units, start with the first slave unit and then the second slave unit).
Wiring
General guidelines
}
Do not lay the connecting cable near or in contact with cables that carry high or highly
volatile currents.