PSEN op2H-SL Series
Operating Manual PSEN op2H-SL Series
1004304-EN-01
38
}
Protected field perimeters
The protected field perimeters (see
Dimensions [
42]
) must completely secure the
hazardous area, making it inaccessible.
}
Response and stopping times must fulfil the requirements in Maintaining the safety dis-
tance
Ensure that the safety light grid's response time and the machine's stopping time fulfil
the requirements in Maintaining the safety distance.
}
No intense or flashing light sources in the vicinity
There may be no especially intense or flashing light sources in the vicinity of the safety
light grid.
}
Ambient conditions
Please observe the
environmental conditions [
14]
.
Operation
Display elements
The safety light grid’s operating status is indicated with LEDs at the connection ends of the
receiver and transmitter.
}
6 LEDs on the receiver for support with alignment, error display and operating status
}
5 LEDs on the transmitter for displaying errors and operating status
1
2
EDM/3
RES
OSSD
PWR
1
2
3
TX
PWR
Receiver
Transmitter