The safety light grid is not equipped with a restart interlock.
If the safety assessment necessitates a restart interlock, this feature must be ensured
within the plant’s programmable safety system. The system may not be started in the haz-
ardous area following a protection violation if personnel are still in the hazardous area.
Prevent circumvention of the protected field. This means that other safety devices and safe-
guards may be required in addition to the safety light grid. These should be determined via
a safety assessment based on the specific application area and specific local conditions
(e.g. official specifications).
Refer to IEC/TS 62046 to determine other necessary safeguards for securing the hazard-
ous area.
Their application must fulfil the site’s relevant national regulations (e. g. EN 60204-1,
NFPA 79:17-7).
The following is deemed improper use in particular:
}
Any component, technical or electrical modification to the product
}
Use of the product outside the areas described in this manual
}
Use of the product outside the technical details (see
Technical details [
43]
).
NOTICE
EMC-compliant electrical installation
The product is designed for use in an industrial environment. The product
may cause interference if installed in other environments. If installed in other
environments, measures should be taken to comply with the applicable
standards and directives for the respective installation site with regard to in-
terference.
Safety regulations
Safety assessment
Before using a unit it is necessary to perform a safety assessment in accordance with the
Machinery Directive.
Functional safety is guaranteed for the product as a single component. However, this does
not guarantee the functional safety of the overall plant/machine. In order to achieve the re-
quired safety level for the overall plant/machine, define the safety requirements for the
plant/machine and then define how these must be implemented from a technical and organ-
isational standpoint.
Use of qualified personnel
The products may only be assembled, installed, programmed, commissioned, operated,
maintained and decommissioned by competent persons.