PSEN op2H-SL Series
Operating Manual PSEN op2H-SL Series
1004304-EN-01
23
[1]
[1]
[2]
[3]
[4]
Legend
[1] Distance from the end of the safety light grid to the position of the C-bracket = ¼ of
the protected field height
[2] M4 screw to attach the C-bracket
[3] M3 screw to position the clamping jaw of the C-bracket
[4] C-bracket
Attach safety light grids using O-brackets
[2]
[1]
Fig.: Detailed view of the O-bracket for the connection end of the safety light grid
Legend
[1] Fixing screw
[2] Coding lug for the connection end of the safety light grid
For safety light grids with a protected field height over 600 mm and strong vibration we re-
commend that you use C-brackets or L-brackets.
1. Make two drill holes in the mounting surface [1], at a distance [5] as stated in the table.
2. Install the two O-brackets [3] and [4] in the correct position and fasten both O-brackets
using the M4 screws.
3. Place the transmitter/receiver between the two O-brackets. The ends of the safety light
grid must lock into position in the O-brackets.
4. Tighten the M4 screws to 1,2 Nm.